[14] | A compact, water-cooled, 144-channel photo sensor module for γ detection in PET (Dohle I. Sand R., et al.), In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2014. |
[13] | A compact, high-density gamma-detection module for Time-of-Flight measurements in PET applications (Sacco I., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015. |
[12] | Very compact, water-cooled SiPM module for PET/MRT applications (Rittweg R. Dand T., et al.), In 2015 European Microelectronics Packaging Conference (EMPC), 2015. |
[11] | Calibration of the non-linear system characteristic of the DSSC detector for the European XFEL (Moch G. Wand D., et al.), In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2015. |
[10] | First operation of a DSSC hybrid 2D soft X-ray imager with 4.5 MHz frame rate (Comotti J. Sand D., et al.), In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), volume , 2016. |
[9] | A Bulk Control Circuit for Open-Loop Front-Ends for X-ray Pixel Detectors (Grande A., et al.), In IEEE Transactions on Nuclear Science, 2017. |
[8] | Qualification of a high-resolution on-chip injection circuit for the calibration of the DSSC X-ray imager for the European XFEL (Guazzoni A. Cand C., et al.), In 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC), volume , 2018. |
[7] | Dual Ring Prototype Electronic System for the Small Animal Fast Insert for MRI (Buck R. Band A., et al.), In 2018 25th IEEE International Conference on Electronics, Circuits and Systems (ICECS), volume , 2018. |
[6] | Charge Sensitive Amplifier With Offset-Compensated V-to-I Converter for the Mini-SDD-Based DSSC Detector (Fiorini A. Gand C., et al.), In IEEE Transactions on Nuclear Science, volume 66, 2019. |
[5] | Calibration strategy of the DSSC X-ray imager (Porro A. Cand M., et al.), In 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), volume , 2019. |
[4] | Characterization of TOF-PET detectors for a second generation radiofrequency-penetrable PET insert for simultaneous PET/MRI (Dong Q, et al.), In 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), IEEE, 2019. |
[3] | Megahertz-rate Ultrafast X-ray Scattering and Holographic Imaging at the European XFEL (Hagström NZ, et al.), 2022. |
[2] | Concepts for the data flow control on the XIDer readout ASIC (Schimansky D., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 1057, 2023. |
[1] | Exploring the time-resolving capabilities of XIDer assemblies (Williams M., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 1057, 2023. |